Coulomb Correlation Between Counterions in the Double Layer Around Cylindrical Polyions
Jesus Piñeroa, Lutful B. Bhuiyana, Jurij Reščičb and Vojko Vlachyb*
aLaboratory of Theoretical Physics Department of Physics, 
University of Puerto Rico San Juan, Puerto Rico 00931-3343
bFaculty of Chemistry and Chemical Technology, University of 
Ljubljana, 1000 Ljubljana, Slovenia
Absrtract
Monte Carlo simulation and theoretical 
results on some aspects of structure and thermodynamics of polyelectrolyte 
solutions at room temperature are presented. The solution is mimicked by an 
infinitely long cylindrical polyion surrounded by point counterions. Both 
standard histogram method and Widom’s particle insertion method are utilized in 
the simulations based on the cylindrical cell model. The osmotic coefficient is 
determined via different equations (approaches) to determine the internal 
consistency of the equations as also the numerical accuracy of the calculations. 
Contributions to the osmotic coefficient arising out of polyion-counterion and 
counterion-counterion interactions are explicitly evaluated. The study clearly 
demonstrates (i) that the good agreement between the Poisson-Boltzmann 
predictions and the simulations is partly due to some serendipitous cancellation 
of errors, and (ii) that it is the neglect of the inter-ionic correlations in 
the mean field approach that leads to a partial compensation of the shortcomings 
of the Poisson-Boltzmann osmotic equation. Simulations results are also reported 
for the ion-ion correlations in the inhomogeneous diffuse double layer 
surrounding the polyion.
Key words: polyelectrolyte solution, Monte Carlo, Poisson-Boltzmann, osmotic coefficient, heat of dilution